Endosonography in Gastroenterology, Gynaecology and Urology

Endosonography in Gastroenterology, Gynaecology and Urology

AngličtinaPevná vazba
Feifel Gernot
Springer-Verlag Berlin and Heidelberg GmbH & Co. KG
EAN: 9783540505037
Titul je vyprodán u vydavatele, prodej skončil
Neznámé datum dodání
1 772 Kč
Běžná cena: 1 969 Kč
Sleva 10 %
Chcete tento titul ještě dnes?
knihkupectví Megabooks Praha Korunní
není dostupné
Librairie Francophone Praha Štěpánská
není dostupné
knihkupectví Megabooks Ostrava
není dostupné
knihkupectví Megabooks Olomouc
není dostupné
knihkupectví Megabooks Plzeň
není dostupné
knihkupectví Megabooks Brno
není dostupné
knihkupectví Megabooks Hradec Králové
není dostupné
knihkupectví Megabooks České Budějovice
není dostupné
knihkupectví Megabooks Liberec
není dostupné

Podrobné informace

Technical improvements over the past twenty years have made endos- copy the procedure of choice for examination of the hollow organs of the genitourinary and gastrointestinal tracts. The development of electro- surgical techniques, laser technology, injection therapy, and a wide variety of other modalities now allow the endoscopist to treat many problems that in the past required open surgery. The simultaneous development of transcutaneous abdominal sonography has had an equally dramatic impact on the practice of gastrointestinal and geni- tourinary surgery. The marriage of these proven technologies, known as endoscopic sonography, provides an exciting new modality that promises to further revolutionize the diagnosis and management of many intraabdominal diseases. Endoscopic sonography opens new frontiers by overcoming the primary limitations of its parent technologies. Fiberoptic endoscopy is limited by the inability to see beyond the luminal surface, this is particularly important when considering neoplastic disease because depth of wall invasion is a key factor in determining treatment. The limiting factor in transcutaneous sonography is the distance between the transducer and the target organ. With endoscopic sonography, the transducer is placed in close proximity to the target organ. This allows the use of high frequency waves (greater than 5 MHz), which provide better tissue resolution and eliminates the image distortion caused by overlying structures.
EAN 9783540505037
ISBN 3540505032
Typ produktu Pevná vazba
Vydavatel Springer-Verlag Berlin and Heidelberg GmbH & Co. KG
Datum vydání 16. července 1990
Stránky 228
Jazyk English
Rozměry 242 x 170
Země Germany
Sekce Professional & Scholarly
Autoři Feifel Gernot
Ilustrace 133 black & white illustrations, 19 black & white tables, biography
Editoři Feifel Gernot; Hildebrandt Ulrich; Mortensen Neil J.